ResidentialCommercialIndustrial

Home

OSFM
 
Services
 
Call
Fort Bragg Fire Sprinkler ProFort Bragg Fire Sprinkler Services

Fire Sprinkler Services
Fort Bragg, California

All installed fire sprinkler systems require service, maintenance, tests and inspections performed to ensure the system will be readily available for operation in case of an emergency according to Fort Bragg Fire Codes, Federal and State Regulations, Manufacturer Specifications, NFPA Standards and Codes, OSHA, Insurance Company Requirements. Any fire sprinkler service should be performed by an actively licensed fire sprinkler company in Fort Bragg.

Fort Bragg Fire Code Compliance

It is the responsibility of the business or property owner to comply with all Fire Codes in the City of Fort Bragg, State of California, Federal, Government or Insurance entities.

  Costs

Estimate of Fire Sprinkler Costs in Fort Bragg

  Estimates

Estimates for Fire Sprinkler Services in Fort Bragg

  Bid Services

Obtain a Fire Sprinkler Service Bid in Fort Bragg

  Design

Designing a Fire Sprinkler System in Fort Bragg

  Engineering

Engineering a Fire Sprinkler System Fort Bragg

  Installation

Installing Fire Sprinkler Systems in Fort Bragg

  Maintenance

Maintaining Fire Sprinkler Systems in Fort Bragg

  Service

Servicing Fire Sprinkler Systems in Fort Bragg

  Repair

Repairing a Fire Sprinkler System in Fort Bragg

  Troubleshooting

Troubleshooting a Fire Sprinkler System in Fort Bragg

  Tests

Testing Fire Sprinkler Systems in Fort Bragg

  Inspections

Inspecting Fire Sprinkler Systems in Fort Bragg

  Annual Tests & Inspections

Annual Fire Sprinkler Tests & Inspections in Fort Bragg

  5 Year Tests & Inspections

5 Year Fire Sprinkler Tests & Inspections in Fort Bragg

  Hydrostatic Tests

Hydrostatic Testing Fire Sprinkler Systems in Fort Bragg

  Flow Tests

Flow Testing Fire Sprinkler Systems in Fort Bragg

 Fort Bragg Temporary Standpipe Fire Sprinklers

Temporary standpipe with FDC Sign

 Temporary standpipes are generally installed in buildings under construction, they are temporary fire protection systems that aid Fort Bragg firefighters at extinguishing fires.

Temporary standpipes are generally dry pipe, lines are void of water, fire department connections (FDC Signs should conspicuosly label connections) allow the City of Fort Bragg fire department access to connect a supply of water to the fill the system and use in attempts to extinguish, contain or stop the spread of fire. Fire pumps, water tanks, and air compressors may aid in increasing pressure, risers, valves, fire hose connections and fire department connections should deliver water all building areas accordingly.

Viking Fire Department Connections

 Many challenges are faced when a building is under construction, remodel or retrofit power and water supplies may still be undeveloped, obstructions may be in the way like equipment, tools & seperations leaving poor access to construction site. This can present many problems for firefighters and the Fort Bragg fire department.

Fort Bragg Fire Sprinklers

Temporary Standpipe Installations

Viking Fire Department Connections

Temporary standpipe, risers, valves, water tanks, fire pumps, air compressors, fire hose and fire department connections (FDC) are generally installed by actively licensed fire sprinkler companies in Fort Bragg.

You can obtain estimates for installation, service and maintenance of temporary standpipe fire sprinklers from actively licensed fire sprinkler companies in Fort Bragg.

Temporary Standpipe
Tests & Inspections

Standpipe Fire Sprinkler Isolation Valve

There are quarterly inspections according to NFPA 25 12.7.1 for fire department connections (FDC).

Semi-annual (6mo), annual (1yr), five year (5yr) tests and inspections that should be completed according to Federal, State, OSHA, Insurance Companies, NFPA standards and codes or the City of Fort Bragg on all installed standpipe fire sprinkler systems.

Temporary standpipes should be inspected and tested for obstructions in protective caps or FDC plugs. Ensure female swivel connections are properly lubricated the threads should be smooth and undamaged, inspect swing check devices or clappers, make sure there are no leaks or an unwanted accumulation of water at outlets. Signs should label and mark each hose connection identifying the standpipe (wet, dry, combination, pre action) connection and zone if any.

Temporary Standpipe
Service & Repair

Fort Bragg Fire Sprinkler Repairs

Fort Bragg Fire Sprinkler Repairs

Being prepared for a fire emergency and having your fire protection ready to operate at all times should be an imperative. You do not want the Fort Bragg fire department and its firefighters to connect to fire hose connections and fire department connections and have bad threads, corroded metal, damaged by impacts, weather conditions or frozen swivels, inoperable or obstructed valves or lack of water pressure.

You should complete any repairs immediately when necessary and have all temporary standpipes serviced on a set schedule according to Federal, State, NFPA, Insurance Companies or the City of Fort Bragg safety, building and fire codes.

 

 Knowledge and Job Experience Counts

When purchasing a fire sprinkler system work with an experienced fire sprinkler company in Fort Bragg. The fire sprinkler technicians knowledge of available systems especially for remodels or retrofits counts to help possibly save you money on costs of installation, service, annual tests & inspections and five year (5yr) fire sprinkler tests & inspections.