Columbus Temporary Standpipes

Temporary standpipe with FDC Sign

Temporary standpipes are generally installed in buildings under construction, they are temporary fire protection systems that aid Columbus firefighters at extinguishing fires.

Temporary standpipes are generally dry pipe, lines are void of water, fire department connections (FDC Signs should conspicuosly label connections) allow the City of Columbus fire department access to connect a supply of water to the fill the system and use in attempts to extinguish, contain or stop the spread of fire. Fire pumps, water tanks, and air compressors may aid in increasing pressure, risers, valves, fire hose connections and fire department connections should deliver water all building areas accordingly.

Viking Fire Department Connections

Many challenges are faced when a building is under construction, remodel or retrofit power and water supplies may still be undeveloped, obstructions may be in the way like equipment, tools & seperations leaving poor access to construction site. This can present many problems for firefighters and the Columbus fire department.

Columbus Fire Sprinklers

Temporary Standpipe Installations

Temporary standpipe, risers, valves, water tanks, fire pumps, air compressors, fire hose and fire department connections (FDC) are generally installed by actively licensed fire sprinkler companies in Columbus.

You can obtain estimates for installation, service and maintenance of temporary standpipe fire sprinklers from actively licensed fire sprinkler companies in Columbus.

Temporary Standpipe
Tests & Inspections

Standpipe Fire Sprinkler Isolation Valve

There are quarterly inspections according to NFPA 25 12.7.1 for fire department connections (FDC).

Semi-annual (6mo), annual (1yr), five year (5yr) tests and inspections that should be completed according to Federal, State, OSHA, Insurance Companies, NFPA standards and codes or the City of Columbus on all installed standpipe fire sprinkler systems.

Temporary standpipes should be inspected and tested for obstructions in protective caps or FDC plugs. Ensure female swivel connections are properly lubricated the threads should be smooth and undamaged, inspect swing check devices or clappers, make sure there are no leaks or an unwanted accumulation of water at outlets. Signs should label and mark each hose connection identifying the standpipe (wet, dry, combination, pre action) connection and zone if any.

Temporary Standpipe
Service & Repair

Being prepared for a fire emergency and having your fire protection ready to operate at all times should be an imperative. You do not want the Columbus fire department and its firefighters to connect to fire hose connections and fire department connections and have bad threads, corroded metal, damaged by impacts, weather conditions or frozen swivels, inoperable or obstructed valves or lack of water pressure.

You should complete any repairs immediately when necessary and have all temporary standpipes serviced on a set schedule according to Federal, State, NFPA, Insurance Companies or the City of Columbus safety, building and fire codes.

Fire Sprinkler Systems

Columbus Fire Sprinklers

Fire Sprinkler Services
Columbus, Georgia

All installed fire sprinkler systems may require service, maintenance, tests and inspections performed to ensure the system will be readily available for operation in case of an emergency. Any fire sprinkler service should be performed by an actively licensed fire sprinkler company in Columbus.

Columbus
Fire Sprinkler Services

Fire Sprinkler Costs
Obtain an Estimate
Bid for Service
Designing a System
Engineering
Installation
Maintenance
Service
Repair
Troubleshooting
Tests
Inspections
Annual Tests & Inspections
5 Year Tests & Inspections
Hydrostatic Tests
Flow Tests

NFPA 13
The NFPA standard and codes for the Installation of Sprinkler Systems

NFPA 14
The NFPA standard and codes for the Installation of Standpipe and Hose Systems

NFPA 15
The NFPA standard and codes for Water Spray Fixed Systems for Fire Protection

NFPA 16
The NFPA standard and codes for the Installation of Foam-Water Sprinkler and Foam-Water Spray Systems

NFPA 20
The NFPA standard and codes for the Installation of Stationary Pumps for Fire Protection

NFPA 25
The NFPA standard and codes for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems

Fire Sprinkler Systems

Fire sprinkler systems are designed to immediately initiate the flow of water, water mist, dry chemical, carbon dioxide (CO2) or similar gas discharge from sprinkler heads in effort to immediately extinguish and/or prevent the fire from spreading.