Buffalo Fire Protection Company
Fire Sprinkler Estimates Fire Sprinkler Installations Fire Sprinkler Repairs Fire Sprinkler Tests and Inspections

Buffalo Private Fire Service Main

A private fire service main is the connection of a water supply from the City of Buffalo, well system or water tank to the fire hydrants, fire sprinklers or standpipe fire sprinkler system of a building, structure or facility. In many cases private fire service mains supply all water to installed fire protection systems.

Fire service mains are installed to ensure a pressurized flow of water will reach all fire protection equipment, hydrants, sprinklers, suppression systems, standpipes, fire hose connections and FDC outlets. Backflow preventers stop any possible water in the fire protection system from flowing back into the potable water supply.

Buffalo Fire Sprinkler Company

To comply with fire codes, when installing new fire sprinkler systems or equipment, servicing and maintaining existing installed fire sprinkler systems or addressing safety and/or fire code violations from the City of Buffalo you'll want affordable, experienced, dependable and reliable help to perform the fire sprinkler services required.

Protect your interests check to ensure the fire sprinkler company is properly and actively licensed to perform the duties required for the specific fire protection system. As each fire protection system may require independent licenses to perform service, repair or installation on fire sprinklers, fire extinguishers, fire suppression systems, fire alarms or fire hydrants in the City of Buffalo.

Buffalo Fire Sprinklers

Fire Service Main Installations

NFPA 24 Standard for Installation of Private Fire Service Main

Fire service mains, meters, water flow detector check valves, single check valves, anti-water hammer check valves, surge arresters, backflow preventers, fire department pumper connections, manually operated valves and fire hydrants may all be installed as part of the fire service main system.

Trenching, laying pipe, backfilling, connecting valves, fittings, hydrants, protect lines from weather and elements (insulating pipes) and initial hydrostatic tests may be required.

You can obtain estimates for installation, service and maintenance of fire service main systems from actively licensed fire protection companies in Buffalo.

Fire Service Main
Tests & Inspections

NFPA 25 Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems

Some municipalities may require monthly or quarterly inspections of hydrants, mainline strainers, piping, fire connection hose cabinets, fire house housings or monitor nozzles.

Yearly there should be annual (1yr) tests and inspections, not to exclude three year (3yr), five year (5yr) tests and inspections that should be completed according to Federal, State, OSHA, Insurance Companies, NFPA standards and codes or the City of Buffalo on all installed private fire service main systems.

Fire Service Main
Service & Repair

Fire service mains may be the primary connection of water supply to all installed fire hydrants, fire sprinklers, or standpipe fire sprinkler system. If the fire service main requires repairs fix them immediately to avoid receiving violations from Buffalo building, safety and fire code inspectors.

You should complete any repairs immediately when necessary and have all private fire service mains serviced on a set schedule according to Federal, State, NFPA, Insurance Companies or the City of Buffalo safety, building and fire codes.

 

Buffalo Private Fire Service Main Tests & Inspections

Tests and inspections should be completed on all installed private fire service mains according to Federal, State, OSHA, Insurance Companies, NFPA standards and codes and the City of Buffalo safety, building and fire codes. A summary of inspections and tests is listed below for fire service main inspections, tests and maintenance.

NFPA 25 standards and codesTable 7.1 Summary of Private Fire Service Mains
NFPA 25
Private Fire Service Main
Inspection, Testing, and Maintenance
Fire Protection Equipment Activity Frequency of Scheduled Inspection NFPA 25
Reference
Hose Houses Inspection Quarterly Tests & Inspections 7.2.2.7
Hydrants (Dry Barrel & Wall) Inspection Annual Inspections and after each Operation 7.2.2.4
Monitor Nozzles Inspection Semi-annual Inspections 7.2.2.6
Hydrants (Wet Barrel) Inspection Annual Inspections and after each Operation 7.2.2.5
Mainline Strainers Inspection Annually, after Operation or Significant Flow 7.2.2.3
Piping (Exposed) Inspection Annual Inspections 7.2.2.1
Piping (Underground) Inspection See 7.2.2.2 (Underground pipes difficult to inspect) 7.2.2.2
Monitor Nozzles Test Flow Annually (Range and Operation) 7.3.3
Hydrants Test Flow Annually 7.3.2
Piping (Exposed and Underground) Flow Test Every five years (5yrs) 7.3.1
Mainline Strainers Maintenance Annual Inspections and after each Operation 7.4.2
Hose Houses Maintenance Annual Inspections 7.4.5
Hydrants Maintenance Annual Inspections 7.4.3
Monitor Nozzles Maintenance Annual Inspections 7.4.4

Fire Sprinkler Systems

Buffalo Fire Sprinklers

Fire Sprinkler Services
Buffalo, New York

All installed fire sprinkler systems may require service, maintenance, tests and inspections performed to ensure the system will be readily available for operation in case of an emergency. Any fire sprinkler service should be performed by an actively licensed fire sprinkler company in Buffalo.

Buffalo
Fire Sprinkler Services

Fire Sprinkler Costs
Obtain an Estimate
Bid for Service
Designing a System
Engineering
Installation
Maintenance
Service
Repair
Troubleshooting
Tests
Inspections
Annual Tests & Inspections
5 Year Tests & Inspections
Hydrostatic Tests
Flow Tests

NFPA 13
The NFPA standard and codes for the Installation of Sprinkler Systems

NFPA 14
The NFPA standard and codes for the Installation of Standpipe and Hose Systems

NFPA 15
The NFPA standard and codes for Water Spray Fixed Systems for Fire Protection

NFPA 16
The NFPA standard and codes for the Installation of Foam-Water Sprinkler and Foam-Water Spray Systems

NFPA 20
The NFPA standard and codes for the Installation of Stationary Pumps for Fire Protection

NFPA 25
The NFPA standard and codes for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems

Fire Sprinkler Systems

Fire sprinkler systems are designed to immediately initiate the flow of water, water mist, dry chemical, carbon dioxide (CO2) or similar gas discharge from sprinkler heads in effort to immediately extinguish and/or prevent the fire from spreading.