Waco Fire Protection Company
Fire Sprinkler Estimates Fire Sprinkler Installations Fire Sprinkler Repairs Fire Sprinkler Tests and Inspections

Waco Pre Action Standpipe Sprinkler Systems

Viking Pre Action Valves

Pre action standpipe fire sprinklers are installed where an accidental flow of water from fire hose connections, fire department connections, fault valves or sprinkler heads would destroy property, appliances or inventory. Pre action sprinklers are generally void and remain dry of fire extinguishing agents such as water, foam concentrates, chemicals or gases such as carbon dioxide (CO2) until the detectors and sensors are triggered from heat, a fire condition or explosion. This system is combines the ease of wet standpipe fire sprinklers reaction times to fire events with the beauty of a dry standpipe system void of water until times of emergency.

Pre action standpipe fire sprinklers are installed in areas where accidental water discharge could potentially damage data centers, computers, museum or art galleries, files, computers, laboratories, or other sensitive appliances or materials or in colder climates where lines may freeze. Accidental discharge of water could be from broken sprinkler heads that are faulty and do not open or frozen, ruptured or broken sprinkler lines. Pre action systems are very complex and should be installed, maintained, serviced, tested and inspected by experienced fire sprinkler companies in Waco.

Single Interlock Preaction System

Viking Singlelock Preaction Valve

Similar to a dry standpipe fire sprinkler system a single interlock pre action system keeps all lines and sprinkler heads void of fire extinguishing agents such as water, foam, chemical or gas like carbon dioxide (CO2) until the detectors and sensors trigger an event due to fire conditions present. Pre action single interlock systems use special pressure regulating valves that keep lines empty, once an event triggers the single interlock pre action system fills with extinguishing agent which disperses from sprinkler heads.

The advantage to installing a single interlock pre action system over dry standpipe is the reaction time of sprinklers to respond to fire can be faster. Reaction to a fire can greatly assist in extinguishing, suppressing or containing the rapid spread of fire. Single interlock pre action sprinkler systems are complex and should be installed, serviced, repaired and maintained by experienced actively licensed fire sprinkler companies in Waco.

Double Interlock Preaction System

Viking Double Interlock Preaction ValveDouble interlock pre action system keeps all lines and sprinkler heads void of liquids until the event of actual fire or explosion. The double interlock pre action system features additional fail safe actuators, sensors and detectors that also must be triggered for the system to release fire extinguishing agents such as water, foam, chemical or gas like carbon dioxide (CO2).

Double interlock pre action systems have reduced failure rates from malfunctions or damage to sprinkler heads or piping from broken lines, heads or valves. Reaction times can be impaired with these systems depending on the manufacturer, valves, heads, devices and components used. Double interlock pre action standpipe sprinkler systems are complex and should be installed, serviced, repaired and maintained by experienced actively licensed fire sprinkler companies in Waco.

Waco Preaction Fire Protection | Installations

Hydraulic calculations are initially done to ensure adequate water supply, backflow preventers are installed to stop back flow of water into freshwater systems. Every design detail of the installation down to where each fire hose connection, fire department connection, fire sprinkler heads are located, how many alarm valves, sprinkler alarm switches, sprinkler heads, pipe hangers, supports and valves is crucial to the preaction standpipe fire sprinkler engineering, function & operation.

You'll want an experienced fire sprinkler company, possibly a fire protection engineer (FPE) to design, engineer and install an preaction fire sprinkler system as they are very complex systems for ordinary contractor or subcontractors and for bond and insurance purposes. In Waco fire sprinkler companies that are confident with preaction standpipe fire sprinklers will offer their estimates, bids or quotes to service, maintain, test, inspect or install the systems.

Waco Fire Sprinklers

Class of Fire Protection

Class A Fire ProtectionClass B Fire ProtectionClass C Fire ProtectionClass D Fire Protection

Preaction standpipe fire sprinklers can be designed to extinguish fires designated as Class A fires such as organic solid material, cloth or wood, Class B fires that involve flammable liquids such as petroleum, solvents, gas or oil, Class C fires that involve electricity and with foam concentrates available class D fires including combustible or explosive metals.

Preaction Standpipe Fire Sprinkler Installation

Standpipe Fire Hose with Metal Cabinet

Preaction standpipe fire sprinkler systems are often installed in apartments, skyscrapers, high rise buildings, condos, dormitories, elder and adult living homes, nursing homes, care facilities, museums, galleries, restaurants, kitchens, stores, malls, gas stations, hotels, motels, banks, supermarkets, hospitals, colleges, parking garages, churches, temples, franchise restaurants, day care centers, auto body and paint spray booths, hospitals, trauma centers, children's hospitals, clinics, schools, libraries, subways, train stations, airports, hangars, water districts, power plants, heliports, chemical plants, offshore platforms, mining facilities, pumping stations, marine or naval ships, military base, jails or prisons.

You can obtain estimates for installation, service and maintenance of preaction standpipe fire sprinklers from actively licensed fire sprinkler companies in Waco.

Standpipe Fire Department Hose Connections

Preaction Standpipe Fire Sprinklers
Service & Maintenance

Standpipe Fire Protection Systems

Preaction standpipe fire sprinkler systems are complex and generally require an experienced fire sprinkler company in Waco to service installed systems.

There are semi-annual (6mo), annual (1yr), five year (5yr) tests and inspections that should be completed according to Federal, State, OSHA, Insurance Companies, NFPA standards and codes or the City of Waco on all installed preaction standpipe fire sprinkler systems. Fire sprinkler systems should be installed, serviced and maintained by actively licensed fire sprinkler companies in Waco.

Waco Fire Sprinklers

Types of Fire Sprinkler Systems

Waco Fire Sprinkler Systems

Fire sprinkler systems are designed, engineered & installed for specific use such as:

High rise buildings or large structures may require the installation and use of commercial or industrial fire sprinkler systems such as:

Fire Sprinkler Systems

Waco Fire Sprinklers

Fire Sprinkler Services
Waco, Texas

All installed fire sprinkler systems may require service, maintenance, tests and inspections performed to ensure the system will be readily available for operation in case of an emergency. Any fire sprinkler service should be performed by an actively licensed fire sprinkler company in Waco.

Waco
Fire Sprinkler Services

Fire Sprinkler Costs
Obtain an Estimate
Bid for Service
Designing a System
Engineering
Installation
Maintenance
Service
Repair
Troubleshooting
Tests
Inspections
Annual Tests & Inspections
5 Year Tests & Inspections
Hydrostatic Tests
Flow Tests

NFPA 13
The NFPA standard and codes for the Installation of Sprinkler Systems

NFPA 14
The NFPA standard and codes for the Installation of Standpipe and Hose Systems

NFPA 15
The NFPA standard and codes for Water Spray Fixed Systems for Fire Protection

NFPA 16
The NFPA standard and codes for the Installation of Foam-Water Sprinkler and Foam-Water Spray Systems

NFPA 20
The NFPA standard and codes for the Installation of Stationary Pumps for Fire Protection

NFPA 25
The NFPA standard and codes for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems

Fire Sprinkler Systems

Fire sprinkler systems are designed to immediately initiate the flow of water, water mist, dry chemical, carbon dioxide (CO2) or similar gas discharge from sprinkler heads in effort to immediately extinguish and/or prevent the fire from spreading.