Dana Point Wet Pipe Fire Sprinklers

Wet pipe systems have water in the pipes at all times, they are quick to respond to fire emergencies as there is not a delay in the water reaching fire sprinkler heads, fire department connections or fire hose connections installed throughout the fire sprinkler zone.
Wet pipe sprinklers are one of the most common types of fire sprinklers to install due to the systems simplicity and the affordable supply of parts, valves, risers, sprinkler heads and components. Due to the fact there are fewer moving parts of the wet pipe fire sprinkler system it will generally cost less to install, service, maintain, test or inspect as will be required by Federal, State, OSHA, Insurance Companies or the City of Dana Point safety, building and fire codes.
Water is one of the most cost effective and affordable fire extinguishing agents available.
Wet pipe sprinklers are one of the most common types of fire sprinklers to install due to the systems simplicity and the affordable supply of parts, valves, risers, sprinkler heads and components.
Wet Pipe Fire Sprinklers | Caution with Freezing Temperatures
Caution should be taken for freezing climates. Wet pipe systems are often installed in heated buildings and any exposed pipes are insulated to protect from cold weather conditions. In cold weather climates, if the ambient temperature drops below freezing, if the building, structure or facility will be exposed to outside elements where very low temperatures exist you may consider antifreeze fire sprinklers, dry pipe fire sprinklers or fire suppression systems as an alternative to installing wet pipe fire sprinklers.
Dana Point Wet Pipe Fire Sprinkler Installations


Hydraulic calculations are initially done to ensure adequate water supply, backflow preventers are installed to stop back flow of water into freshwater systems. Every design detail of the installation down to where each fire department connection, fire hose connections and fire sprinkler heads are located, how many alarm valves, sprinkler alarm switches, water tanks, fire pumps, pipe hangers, supports and valves is crucial to the wet pipe fire sprinkler engineering, function & operation.
You'll want an experienced fire sprinkler company, possibly a fire protection engineer (FPE) to design, engineer and install a wet pipe fire sprinkler system for bond and insurance purposes. In Dana Point fire sprinkler companies that are confident with wet pipe fire sprinklers will offer their estimates, bids or quotes to service, maintain, test, inspect or install the systems.
-
Wet Pipe Fire Sprinklers: Class of Fire Protection
-
Wet pipe fire sprinklers can be designed to extinguish fires designated as Class A fires such as organic solid material, cloth or wood, Class B fires that involve flammable liquids such as petroleum, solvents, gas or oil, Class C fires that involve electricity and with foam concentrates available class D fires including combustible or explosive metals.
- Class A fires such as organic solid material, cloth or wood
- Class B fires that involve flammable liquids such as petroleum, solvents, gas or oil
- Class C fires that involve electricity
- Class D fires including combustible or explosive metals.
-
Dana Point Wet Pipe Fire Sprinkler Installation | Dana Point Fire Sprinkler Services
-
Fire Sprinkler Installation in Dana Point
Wet pipe fire sprinkler systems are often installed in apartments, skyscrapers, high rise buildings, condos, dormitories, elder and adult living homes, nursing homes, care facilities, museums, galleries, restaurants, kitchens, stores, malls, gas stations, hotels, motels, banks, supermarkets, hospitals, colleges, parking garages, churches, temples, franchise restaurants, day care centers, auto body and paint spray booths, hospitals, trauma centers, children's hospitals, clinics, schools, libraries, subways, train stations, airports, hangars, water districts, power plants, heliports, chemical plants, offshore platforms, mining facilities, pumping stations, marine or naval ships, military base, jails or prisons.
You can obtain estimates for installation, service and maintenance of wet pipe fire sprinklers from actively licensed fire sprinkler companies in Dana Point.
-
Wet Pipe Fire Sprinklers Service & Maintenance | Dana Point Fire Sprinkler Services
-
Dana Point Fire Sprinkler Service & Maintenance

Wet pipe fire sprinklers are very reliable & affordable to maintain or repair in Dana Point. They are water based & can be fed through the City of Dana Point water supply, portable temporary tanks or water tanks.
There are semi-annual (6mo), annual (1yr), five year (5yr) tests and inspections that should be completed according to Federal, State, OSHA, Insurance Companies, NFPA standards and codes or the City of Dana Point on all installed wet pipe fire sprinkler systems. Fire sprinkler systems should be installed, serviced and maintained by actively licensed fire sprinkler companies in Dana Point.
-
Types of Fire Sprinkler Systems in Dana Point, California
| Dana Point Fire Sprinkler Services
-
The Importance of Installing Fire Sprinklers

Below is a list of the most common types of fire sprinkler systems to install in Dana Point, California.
Fire sprinkler systems are designed, engineered & installed for specific use and to ensure proper coverage you should contact a licensed fire sprinkler company in Dana Point or the local fire marshal to help determine what systems will provide fire protection coverage and help you remain fire code compliant.
High rise buildings or large structures may require the installation and use of commercial or industrial fire sprinkler systems such as:
Knowledge and Job Experience Counts
When purchasing a fire sprinkler system work with an experienced fire sprinkler company in Dana Point. The fire sprinkler technicians knowledge of available systems especially for remodels or retrofits counts to help possibly save you money on costs of installation, service, annual tests & inspections and five year (5yr) fire sprinkler tests & inspections.