Columbus Fire Protection Company
Fire Sprinkler Estimates Fire Sprinkler Installations Fire Sprinkler Repairs Fire Sprinkler Tests and Inspections

Columbus Standpipe Fire Sprinklers

Standpipe Fire Sprinklers with NFPA Sign

Standpipe systems are designed and engineered to deliver an adequate pressurized volume of water to each of the designated fire department connections (FDC) to attach fire hose connections aiding building occupants or the Columbus fire department in fighting a fire. This allows firefighters easy access to fire department connections on every story and floor of a building or to isolated buildings, structures or facilities. A valve will easily open all fire department connections plumbed in that zone and supply a pressurized volume of water to all connections.

Standpipe systems play an important role in protecting multi-floor, multi-story, large facilities, yards, structures or buildings in Columbus. Standpipe systems may have installed vertical sprinkler pipes known as "risers" and horizontal sprinkler pipes installed throughout the building or facility. Fire pumps may be used to increase water pressure, increasing the PSI of water is referred to as “total head”, sprinkler systems work best when there is an adequate pressurized water supply to feed fire sprinkler systems and standpipe sprinkler systems. Water tanks can be installed on the roof of a building allowing gravity to assist increasing water pressure this is called a gravity fed pressurized system.

Standpipe Fire Sprinkler Systems in Columbus

Standpipe fire sprinkler systems should be serviced, maintained and repaired when necessary by actively licensed fire sprinkler companies in Columbus. Help keep Columbus safe from the dangers fire poses, follow all safety, building and/or fire code rules and regulations in Columbus and practice fire prevention.
Standpipe Fire Sprinkler Systems in Columbus

Viking Fire Department Connections

Columbus Fire Protection

Federal, State, OSHA, Insurance Companies or the City of Columbus may require you to install, service and maintain fire sprinkler systems, fixed, portable or wheeled fire extinguishers, fire suppression systems, fire hoses, buckets, axes, fire hooks, fire doors, fire hydrants and/or fire alarm systems. Fire diamond NFPA signs are available to mark hazardous materials, explosive materials or special hazards. Signs should clearly mark all fire protection equipment and exits of the building making it easy for the building occupants to navigate to emergency exits and for the Columbus fire department or emergency personnel to navigate to desired fire protection or life safety systems.

Available Standpipe Systems in Columbus

Standpipe System for Facility and Yard

Standpipe systems are available for specific fire hazards, hazardous materials, explosive materials or special hazards fire protection coverage. Standpipe systems are designed and engineered to help building occupants, emergency personnel or firefighters in containing the rapid spread of fire, suppressing or extinguishing the fire completely.

Types of Standpipe Systems

Standpipe System Classifications

Standpipe systems are classified specifically for the occupants, emergency personnel and firefighters who use them.

  • Class I Standpipes:
    Designed for use by professional fire fighters.
  • Class II Standpipes:
    Designed for building occupants to use
  • Class III Standpipes:
    Designed both for occupants & firefighters

Wet Standpipe Systems

Columbus Wet Standpipe
Fire Sprinkler Systems

Wet standpipe systems have water in the pipes at all times, they are quick to respond to fire emergencies as there is not a delay in the water reaching fire sprinkler heads, fire department connections or fire hose connections.

Wet standpipe systems are the most commonly installed standpipe system. Caution should be taken for freezing climates. Wet standpipe systems are often installed in heated buildings and any exposed pipes are insulated to protect from cold weather conditions.

Dry Standpipe Systems

Columbus Dry Standpipe
Fire Sprinkler Systems

Fire extinguishing agents such as water, foam, chemical or gas like carbon dioxide (CO2) are generally kept void from the system under normal conditions by regulating air pressure with dry pipe valves.

This allows for an automatic supply of water if one of the fire department connections or fire hose connections valves are opened. If the need for rapid response is required fire pumps, accelerator or exhauster systems can be installed to expedite the flow.

Manual Standpipe Systems

Columbus Manual Standpipe
Fire Sprinkler Systems

Manual standpipe systems are generally kept dry or free from any water or liquids. When there is a fire present firefighters are able to connect a water supply thus feeding the standpipe system allowing water to discharge from all fire department connections zoned on the manual standpipe line.

Combination Standpipe Systems

Columbus Combination Standpipe
Fire Sprinkler Systems

Fire sprinkler companies in Columbus are able to install combination of automatic fire sprinklers, dry standpipe, pre action and wet standpipe systems helping you protect all specific fire hazards, hazardous materials, explosive materials or special hazards.

When fire protection systems are combined you'll want to work with experienced fire protection companies in Columbus. Ensure any subcontractors are fully insured and actively licensed in Columbus before performing installation, service, repair or maintenance.

Antifreeze Standpipe Systems

Columbus Antifreeze Standpipe
Fire Sprinkler Systems

Antifreeze standpipe systems are designed for cold climates where ambient temperatures may drop below freezing causing water lines to rupture, burst or freeze.

Use factory premixed antifreeze solutions, there are limits to the percentage of glycerin, propylene and glycol contained in the standpipe system check safety, building and fire codes in Columbus. Cold weather design and installation practices should be used to protect the system from freezing such as installing pipe insulation.

Pre Action Standpipe Systems

Columbus Pre Action Standpipe
Fire Sprinkler Systems

Pre action standpipe systems are installed where an accidental flow of water from sprinkler heads, fire department connections or fire hose connections would destroy property, appliances or inventory.

Pre action standpipe systems are generally void and remain dry of fire extinguishing agents such as water, foam concentrates, chemicals or gases such as carbon dioxide (CO2) until the detectors and sensors are triggered from heat, a fire condition or explosion. This system is combines the ease of wet pipe standpipe systems reaction times to fire events with the beauty of a dry standpipe system void of water until times of emergency.

Multi-Zoned Standpipe Systems

If vertical and/or horizontal separations or subdivisions are required by safety, building or fire codes in Columbus you may need a zoned system. An independent water supply normally feeds each of these standpipe zones which helps regulate pressure in the standpipe system.

Multi zoned systems allow for combination sprinkler and standpipe systems to be installed into zones of your facility that require specific fire coverage for fire hazards present. Without compromising standpipe systems or the systems pressure into each of the zones.

Fire Sprinkler Systems

Columbus Fire Sprinklers

Fire Sprinkler Services
Columbus, Georgia

All installed fire sprinkler systems may require service, maintenance, tests and inspections performed to ensure the system will be readily available for operation in case of an emergency. Any fire sprinkler service should be performed by an actively licensed fire sprinkler company in Columbus.

Columbus
Fire Sprinkler Services

Fire Sprinkler Costs
Obtain an Estimate
Bid for Service
Designing a System
Engineering
Installation
Maintenance
Service
Repair
Troubleshooting
Tests
Inspections
Annual Tests & Inspections
5 Year Tests & Inspections
Hydrostatic Tests
Flow Tests

NFPA 13
The NFPA standard and codes for the Installation of Sprinkler Systems

NFPA 14
The NFPA standard and codes for the Installation of Standpipe and Hose Systems

NFPA 15
The NFPA standard and codes for Water Spray Fixed Systems for Fire Protection

NFPA 16
The NFPA standard and codes for the Installation of Foam-Water Sprinkler and Foam-Water Spray Systems

NFPA 20
The NFPA standard and codes for the Installation of Stationary Pumps for Fire Protection

NFPA 25
The NFPA standard and codes for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems

Fire Sprinkler Systems

Fire sprinkler systems are designed to immediately initiate the flow of water, water mist, dry chemical, carbon dioxide (CO2) or similar gas discharge from sprinkler heads in effort to immediately extinguish and/or prevent the fire from spreading.