Columbus Fire Protection Company
Fire Sprinkler Estimates Fire Sprinkler Installations Fire Sprinkler Repairs Fire Sprinkler Tests and Inspections

Standpipe Fire Sprinkler Systems in Columbus

Viking Fire Department Connections

Standpipe systems play an important role in protecting multi-floor, multi-story, large facilities, yards, structures or buildings in Columbus from fire. Standpipe systems may have installed vertical sprinkler pipes known as "risers" and horizontal sprinkler pipes installed throughout the building or facility. Fire pumps may be used to increase water pressure, increasing the PSI of water is referred to as “total head”, sprinkler systems work best when there is an adequate pressurized water supply to feed fire sprinkler systems and standpipe sprinkler systems. Water tanks can be installed on the roof of a building allowing gravity to assist increasing water pressure this is called a gravity fed pressurized system.

Standpipe System for Facility and Yard

Standpipe Fire Sprinkler Service & Maintenance in Columbus

Every standpipe system has a frequency of required tests and inspections that should be completed according to the schedule created by the manufacturers recommendations, Federal, State, OSHA, NFPA standards and codes or the City of Columbus safety, building and/or fire codes. During the course of semi-annual, annual, yearly or five year (5yr) tests and inspections technicians may note there are repairs to be completed prior to receiving certificates of completion. Standpipe fire sprinkler systems should be serviced, maintained and repaired when necessary by actively licensed fire sprinkler companies in Columbus.

Available Standpipe Systems in Columbus

Standpipe systems are available for specific fire hazards, hazardous materials, explosive materials or special hazards fire protection coverage. Standpipe systems are designed and engineered to help building occupants, emergency personnel or firefighters in containing the rapid spread of fire, suppressing or extinguishing the fire completely.
Columbus Standpipe Fire Sprinklers

Columbus Fire Sprinklers

Class of Fire Protection

Class A Fire ProtectionClass B Fire ProtectionClass C Fire ProtectionClass D Fire Protection

Standpipe fire sprinklers can be designed to extinguish fires designated as Class A fires such as organic solid material, cloth or wood, Class B fires that involve flammable liquids such as petroleum, solvents, gas or oil, Class C fires that involve electricity and with foam concentrates available class D fires including combustible or explosive metals.

Standpipe Fire Sprinkler Installation

Standpipe Fire Sprinkler Isolation Valve

Standpipe fire sprinkler systems are often installed in apartments, skyscrapers, high rise buildings, condos, dormitories, elder and adult living homes, nursing homes, care facilities, museums, galleries, restaurants, kitchens, stores, malls, gas stations, hotels, motels, banks, supermarkets, hospitals, colleges, parking garages, churches, temples, franchise restaurants, day care centers, auto body and paint spray booths, hospitals, trauma centers, children's hospitals, clinics, schools, libraries, subways, train stations, airports, hangars, water districts, power plants, heliports, chemical plants, offshore platforms, mining facilities, pumping stations, marine or naval ships, military base, jails or prisons.

You can obtain estimates for installation, service and maintenance of standpipe fire sprinklers from actively licensed fire sprinkler companies in Columbus.

Standpipe Fire Department Hose Connections

Standpipe Fire Sprinkler
Service & Maintenance

Standpipe Fire Hose with Metal Cabinet
Potter Roemer Model 1300 Series
Metal Fire Hose Cabinet
Standpipe & Fire Department Connections

Standpipe fire sprinklers have valves, risers, fire pumps, fire hose connections, devices and components. Repairs or service may be required in the standpipe system if there is an empty tank, a break or major leak in the system’s water piping, frozen, ruptured or broken lines, inoperable shut off supply valves, defective fire department connections, complete or partial construction related shut downs affecting more than one floor or for a planned standpipe removal.

There are semi-annual (6mo), annual (1yr), five year (5yr) tests and inspections that should be completed according to Federal, State, OSHA, Insurance Companies, NFPA standards and codes or the City of Columbus on all installed standpipe fire sprinkler systems. Fire sprinkler systems should be installed, serviced and maintained by actively licensed fire sprinkler companies in Columbus.

Columbus Fire Sprinklers

Types of Fire Sprinkler Systems

Columbus Fire Sprinkler Systems

Fire sprinkler systems are designed, engineered & installed for specific use such as:

High rise buildings or large structures may require the installation and use of commercial or industrial fire sprinkler systems such as:

Fire Sprinkler Systems

Columbus Fire Sprinklers

Fire Sprinkler Services
Columbus, Georgia

All installed fire sprinkler systems may require service, maintenance, tests and inspections performed to ensure the system will be readily available for operation in case of an emergency. Any fire sprinkler service should be performed by an actively licensed fire sprinkler company in Columbus.

Columbus
Fire Sprinkler Services

Fire Sprinkler Costs
Obtain an Estimate
Bid for Service
Designing a System
Engineering
Installation
Maintenance
Service
Repair
Troubleshooting
Tests
Inspections
Annual Tests & Inspections
5 Year Tests & Inspections
Hydrostatic Tests
Flow Tests

NFPA 13
The NFPA standard and codes for the Installation of Sprinkler Systems

NFPA 14
The NFPA standard and codes for the Installation of Standpipe and Hose Systems

NFPA 15
The NFPA standard and codes for Water Spray Fixed Systems for Fire Protection

NFPA 16
The NFPA standard and codes for the Installation of Foam-Water Sprinkler and Foam-Water Spray Systems

NFPA 20
The NFPA standard and codes for the Installation of Stationary Pumps for Fire Protection

NFPA 25
The NFPA standard and codes for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems

Fire Sprinkler Systems

Fire sprinkler systems are designed to immediately initiate the flow of water, water mist, dry chemical, carbon dioxide (CO2) or similar gas discharge from sprinkler heads in effort to immediately extinguish and/or prevent the fire from spreading.