Columbus Fire Protection Company
Fire Sprinkler Estimates Fire Sprinkler Installations Fire Sprinkler Repairs Fire Sprinkler Tests and Inspections

Columbus Dry Standpipe Sprinkler Systems

Standpipe Fire Sprinklers with NFPA Sign

Dry standpipe fire sprinklers are designed and engineered to keep all lines, fire department connections, fire hose connections and sprinkler heads void of fire extinguishing agents such as water, foam, chemical or gas like carbon dioxide (CO2) until the detectors and sensors trigger an event due to fire conditions present, heat, explosion or fire is detected. In Columbus work with experienced fire sprinkler companies familiar with dry standpipe systems to install, service or maintain according to safety, building or fire codes.

Standpipe systems are designed and engineered to deliver an adequate pressurized volume of water to each of the designated fire department connections (FDC) to attach fire hose connections aiding building occupants or the Columbus fire department in fighting a fire. This allows firefighters easy access to fire department connections on every story and floor of a building or to isolated buildings, structures or facilities. A valve will easily open all fire department connections plumbed in that zone and supply a pressurized volume of water to all connections.

Viking Model F Dry Sprinkler Valve

Dry Standpipe Fire Protection

Standpipe systems play an important role in protecting multi-floor, multi-story, large facilities, yards, structures or buildings in Columbus. Standpipe systems may have installed vertical sprinkler pipes known as "risers" and horizontal sprinkler pipes installed throughout the building or facility. Fire pumps may be used to increase water pressure, increasing the PSI of water is referred to as “total head”, sprinkler systems work best when there is an adequate pressurized water supply to feed fire sprinkler systems and standpipe sprinkler systems. Water tanks can be installed on the roof of a building allowing gravity to assist increasing water pressure this is called a gravity fed pressurized system.

Dry standpipe systems are used in cold weather climates, when colder temperatures are a factor dry pipe fire sprinklers are often installed to avoid freezing temperatures which may cause wet pipe sprinkler lines to burst or rupture.

Tyco Dry Pipe Fire Sprinkler System Diagram

Columbus Dry Standpipe Fire Protection | Installations

Hydraulic calculations are initially done to ensure adequate water supply, backflow preventers are installed to stop back flow of water into freshwater systems. Every design detail of the installation down to where each fire sprinkler head is located, how many alarm valves, sprinkler alarm switches, sprinkler heads, fire department connections, pipe hangers, supports and valves is crucial to the dry pipe fire sprinkler engineering, function & operation.

You'll want an experienced fire sprinkler company, possibly a fire protection engineer (FPE) to design, engineer and install a dry standpipe fire sprinkler system as they are very complex systems for ordinary contractor or subcontractors and for bond and insurance purposes. In Columbus fire sprinkler companies that are confident with dry standpipe fire sprinklers will offer their estimates, bids or quotes to service, maintain, test, inspect or install the systems.

Columbus Fire Sprinklers

Class of Fire Protection

Class A Fire ProtectionClass B Fire ProtectionClass C Fire ProtectionClass D Fire Protection

Dry standpipe fire sprinklers can be designed to extinguish fires designated as Class A fires such as organic solid material, cloth or wood, Class B fires that involve flammable liquids such as petroleum, solvents, gas or oil, Class C fires that involve electricity and with foam concentrates available class D fires including combustible or explosive metals.

Dry Standpipe Fire Sprinkler Installation

Standpipe Fire Hose with Metal Cabinet

Dry standpipe fire sprinkler systems are often installed in apartments, skyscrapers, high rise buildings, condos, dormitories, elder and adult living homes, nursing homes, care facilities, museums, galleries, restaurants, kitchens, stores, malls, gas stations, hotels, motels, banks, supermarkets, hospitals, colleges, parking garages, churches, temples, franchise restaurants, day care centers, auto body and paint spray booths, hospitals, trauma centers, children's hospitals, clinics, schools, libraries, subways, train stations, airports, hangars, water districts, power plants, heliports, chemical plants, offshore platforms, mining facilities, pumping stations, marine or naval ships, military base, jails or prisons.

You can obtain estimates for installation, service and maintenance of dry standpipe fire sprinklers from actively licensed fire sprinkler companies in Columbus.

Standpipe Fire Department Hose Connections

Dry Standpipe Fire Sprinklers
Service & Maintenance

Standpipe Fire Protection Systems

Dry standpipe fire sprinkler systems are complex and generally require an experienced fire sprinkler company in Columbus to service installed systems.

There are semi-annual (6mo), annual (1yr), five year (5yr) tests and inspections that should be completed according to Federal, State, OSHA, Insurance Companies, NFPA standards and codes or the City of Columbus on all installed dry standpipe fire sprinkler systems. Fire sprinkler systems should be installed, serviced and maintained by actively licensed fire sprinkler companies in Columbus.

Columbus Fire Sprinklers

Types of Fire Sprinkler Systems

Columbus Fire Sprinkler Systems

Fire sprinkler systems are designed, engineered & installed for specific use such as:

High rise buildings or large structures may require the installation and use of commercial or industrial fire sprinkler systems such as:

Fire Sprinkler Systems

Columbus Fire Sprinklers

Fire Sprinkler Services
Columbus, Georgia

All installed fire sprinkler systems may require service, maintenance, tests and inspections performed to ensure the system will be readily available for operation in case of an emergency. Any fire sprinkler service should be performed by an actively licensed fire sprinkler company in Columbus.

Columbus
Fire Sprinkler Services

Fire Sprinkler Costs
Obtain an Estimate
Bid for Service
Designing a System
Engineering
Installation
Maintenance
Service
Repair
Troubleshooting
Tests
Inspections
Annual Tests & Inspections
5 Year Tests & Inspections
Hydrostatic Tests
Flow Tests

NFPA 13
The NFPA standard and codes for the Installation of Sprinkler Systems

NFPA 14
The NFPA standard and codes for the Installation of Standpipe and Hose Systems

NFPA 15
The NFPA standard and codes for Water Spray Fixed Systems for Fire Protection

NFPA 16
The NFPA standard and codes for the Installation of Foam-Water Sprinkler and Foam-Water Spray Systems

NFPA 20
The NFPA standard and codes for the Installation of Stationary Pumps for Fire Protection

NFPA 25
The NFPA standard and codes for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems

Fire Sprinkler Systems

Fire sprinkler systems are designed to immediately initiate the flow of water, water mist, dry chemical, carbon dioxide (CO2) or similar gas discharge from sprinkler heads in effort to immediately extinguish and/or prevent the fire from spreading.